4 SERVOPACK Specifications and Dimensional Drawings

4.1.3 Single-phase 220 V (Option)

4.1.3 Single-phase 220 V (Option)
The value of the input power supply voltage is maximum 253 Vrms.
SERVOPACK Model SGDH-
Max. Applicable Servomotor
Capacity (kW)
Continuous Output Current
(Arms)
Max. Output Current (Arms)
Input Power
Supply
Configuration
Regenerative Processing
* When a power supply of 187V (-15% of 220V) or less is used, alarm 41 which indicates voltage short-
age, may occur when accelerating to maximum speed with maximum torque of servomotor.

4.1.4 Three-phase 400 V

The value of the input power supply voltage is maximum 528 Vrms.
SERVOPACK Model SGDH-
Max. Applicable Servomotor
Capacity (kW)
Continuous Output Current
(Arms)
Max. Output Current (Arms)
Input Power
Supply
Configuration
Regenerative Processing
Main Circuit
Single-phase/Three-phase 220 to 230 VAC +10 to -15%, 50/60 Hz
Single-phase 220 to 230 VAC +10 to -15%, 50/60 Hz
Control Circuit
Base-mounted (Rack mounting available as an option)
Built-in
05D
0.45
1.9
5.5
Three-phase 380 to 480 VAC +10 to -15%, 50/60 Hz
Main Circuit
24 VDC ±15%
Control Circuit
Base-mounted
(Rack mounting available as an option)
Built-in
08AE-S
0.75
5.7
13.9
10D
15D
20D
30D
1.0
1.5
2.0
3.0
3.5
5.4
8.4
11.9
8.5
14
20
28
4-4
15AE-S
1.5
11.6
28
50D
60D
75D
1AD
5.0
6.0
7.5
11
16.5
20.8
25.4
28.1
40.5
55
65
70
Base-mounted (Duct-venti-
lated available as an option)
External regenerative resistor
1ED
15
37.2
85