Parameter
No.
Pn50A
Input Signal Selections 1
4th
3rd
digit
digit
n.
Name
Setting Range
2nd
1st
digit
digit
Input Signal Allocation Mode
(Refer to "7.3.2 Input Circuit Signal Allocation.")
Uses the sequence input signal terminals with standard allocation. ∗
0
1
Changes the sequence input signal allocation for each signal.
/S-ON Signal Mapping
Signal Polarity: Normal; Servo ON when ON (L-level)
Signal Polarity: Reverse; Servo ON when OFF (H-level)
(Refer to "8.3.1 Setting the Servo ON Signal.")
0
ON when CN1-40 input signal is ON (L-level).
1
ON when CN1-41 input signal is ON (L-level).
2
ON when CN1-42 input signal is ON (L-level).
3
ON when CN1-43 input signal is ON (L-level).
4
ON when CN1-44 input signal is ON (L-level).
5
ON when CN1-45 input signal is ON (L-level).
6
ON when CN1-46 input signal is ON (L-level).
7
Sets signal ON.
8
Sets signal OFF.
9
OFF when CN1-40 input signal is OFF (H-level).
A
OFF when CN1-41 input signal is OFF (H-level).
B
OFF when CN1-42 input signal is OFF (H-level).
C
OFF when CN1-43 input signal is OFF (H-level).
D
OFF when CN1-44 input signal is OFF (H-level).
E
OFF when CN1-45 input signal is OFF (H-level).
F
OFF when CN1-46 input signal is OFF (H-level).
/P-CON Signal Mapping (P control when ON (L-level))
(Refer to "9.4.4 Proportional Control Operation (Proportional Operation Reference).")
0 to F Same as /S-ON
P-OT Signal Mapping (Overtravel when OFF (H-level))
(Refer to "8.3.3 Setting the Overtravel Limit Function.")
0
Forward run allowed when CN1-40 input signal is ON (L-level).
1
Forward run allowed when CN1-41 input signal is ON (L-level).
2
Forward run allowed when CN1-42 input signal is ON (L-level).
3
Forward run allowed when CN1-43 input signal is ON (L-level).
4
Forward run allowed when CN1-44 input signal is ON (L-level).
5
Forward run allowed when CN1-45 input signal is ON (L-level).
6
Forward run allowed when CN1-46 input signal is ON (L-level).
7
Forward run prohibited.
8
Forward run allowed.
9
Forward run allowed when CN1-40 input signal is OFF (H-level).
A
Forward run allowed when CN1-41 input signal is OFF (H-level).
B
Forward run allowed when CN1-42 input signal is OFF (H-level).
C
Forward run allowed when CN1-43 input signal is OFF (H-level).
D
Forward run allowed when CN1-44 input signal is OFF (H-level).
E
Forward run allowed when CN1-45 input signal is OFF (H-level).
F
Forward run allowed when CN1-46 input signal is OFF (H-level).
Unit
11-37
11.3 List of Parameters
Factory
Setting
Reference
Setting
Validation
Section
2100
After
restart
11