9 Adjustments

9.3.4 Speed Loop Gain

9.3.4 Speed Loop Gain
Pn100
This parameter determines the responsiveness of the speed loop. If the speed loop's responsiveness is too low, it will delay
the outer position loop and cause overshooting and vibration of the speed reference. The SERVOPACK will be most stable
and responsive when the speed loop gain is set as high as possible within the range that does not cause vibration in the
mechanical system. The value of speed loop gain is the same as the set value of Pn100 if the moment of inertia ratio in
Pn103 has been set correctly.
Pn103
Pn103 set value =
The factory setting is Pn103=0. Before adjusting the servo, determine the moment of inertia ratio with the equation above
and set parameter Pn103.

9.3.5 Speed Loop Integral Time Constant

Pn101
The speed loop has an integral element so that the speed loop can respond to minute inputs. This integral element causes a
delay in the SERVOPACK. If the time constant is set too long, overshooting will occur, which results in a longer position-
ing settling time or responsiveness decreases.
The estimated set value for Pn101 depends on the speed loop control method with Pn10B.1, as shown below.
Selecting the Speed Loop Control Method (PI Control or I-P Control)
INFO
Generally, I-P control is more effective in high-speed positioning or high-speed/precision manufacturing applications. The
position loop gain is lower than it would be in PI control, so shorter positioning times and smaller arc radii can be
achieved. On the other hand, PI control is generally used when switching to P control fairly often with a mode switch or
other method.
Speed Loop Gain (Kv)
Setting Range
1 to 2,000
Moment of Inertia Ratio
Setting Range
0 to 10,000
Motor axis conversion load moment of inertia (J
Servomotor rotor moment of inertia (J
Speed Loop Integral Time Constant (Ti)
Setting Range
15 to 51,200
(0.15 to 512.00 ms)
Setting Unit
Factory Setting
Hz
Setting Unit
Factory Setting
%
)
L
×100(%)
)
M
Setting Unit
Factory Setting
0.01 ms
(20.00 ms)