Installation Conditions Of Emc Directives - YASKAWA SGDH User Manual

Servomotors
Hide thumbs Also See for SGDH:
Table of Contents

Advertisement

6.4.3 Installation Conditions of EMC Directives

To adapt a combination of a SGM H servomotor and a SGDH SERVOPACK to EMC Directives (EN50081-2
and EN50082-2), the following conditions must be satisfied.
(1) EMC Installation Conditions
This section describes the installation conditions that satisfy EMC guidelines for each model of the SGDH SER-
VOPACK. The conditions required for the standard type (base mounted) of SERVOPACK are described. Refer
to this section for other SERVOPACK models such as the rack mounted types as well.
This section describes the EMC installation conditions satisfied in test conditions prepared by Yaskawa. The
actual EMC level may differ depending on the actual system's configuration, wiring, and other conditions.
(a) Single-phase 100 V/200 V/220 V
SGDH-A3BE to -02BE (Single-phase 100 VAC, 30 to 200 W)
SGDH-A3AE to -04AE (Single-phase 200 VAC, 30 to 400 W)
SGDH-08AE-S (Single-phase 220 VAC, 750 W)
SGDH-15AE-S (Single-phase 220 VAC, 1.5 kW)
Power Supply
Single-phase
100 VAC or 200 VAC
PE
* Connect main circuit power supply to terminals L1-L3 for SGDH-08AE-S and
SGDH-15AE-S.
Symbol
Noise
filter
Noise
filter
Approx. 2 m (6.56 ft)
Cable Name
I/O Signals cable
Servomotor cable
Encoder cable
AC Line cable
6-23
Ground Plate / Shield Box
Brake power
supply
SERVOPACK
U, V, W
L1, L2
L1C, L2C
CN2
CN1
Core
Approx. 5 m (16.4 ft)
Core
Host controller
Specifications
Shield cable
Shield cable
Shield cable
Shield cable
6.4 Others
Brake
Servo-
motor
6
Encoder
PE