Multiturn Limit Setting When Multiturn Limit Disagreement (A.cc) Occurred - YASKAWA SGDH User Manual

Servomotors
Hide thumbs Also See for SGDH:
Table of Contents

Advertisement

8.4.8 Multiturn Limit Setting When Multiturn Limit Disagreement (A.CC) Occurred

Perform the following operation using the digital operator or panel operator.
This operation can only be done when the A.CC alarm is generated.
Display after
Step
Operation
1
2
3
4
5
6
7
Turn OFF the power, and then turn it ON again to make the setting valid.
Digital
Panel
Operator
Operator
DSPL
SET
MODE/SET
(DSPL/SET Key)
(MODE/SET Key)
DATA
ENTER
DATA/
(DATA/SHIFT Key)
(DATA/ENTER K ey)
(Press at least 1 s.)
DSPL
SET
MODE/SET
(DSPL/SET Key)
(MODE/SET Key)
About one second later
DATA
ENTER
DATA/
(DATA/ENTER K ey)
(DATA/SHIFT Key)
(Press at least 1 s.)
Description
Press the DSPL/SET or MODE/SET Key to select the utility func-
tion mode.
Press the LEFT/RIGHT or UP/DOWN Key or the UP or DOWN
Key to set the parameter Fn013.
*The digit that can be set will blink.
Press the DATA/ENTER Key once, or DATA/SHIFT Key for
more than one second. The display on the left will appear.
Press the DSPL/SET or MODE/SET Key. The multiturn limit set-
ting in the absolute encoder will be changed.
When the setting is completed, "donE" will blink for about one
second.
After "donE" is displayed, "PGSEt" will be displayed again.
Press the DATA/ENTER Key once, or DATA/SHIFT Key for
more than one second to return to the Fn013 display of the utility
function mode.
8-37
8.4 Absolute Encoders
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents