Wiring Main Circuit; Names And Functions Of Main Circuit Terminals - YASKAWA SGDH User Manual

Servomotors
Hide thumbs Also See for SGDH:
Table of Contents

Advertisement

6 Wiring

6.1.1 Names and Functions of Main Circuit Terminals

6.1 Wiring Main Circuit

This section describes typical examples of main circuit wiring, functions of main circuit terminals, and the power
ON sequence.
• Do not bundle or run power and signal lines together in the same duct. Keep power and signal lines sepa-
rated by at least 300 mm (11.81 in).
Failure to observe this caution may result in malfunction.
• Use twisted-pair shielded wires or multi-core twisted pair shielded wires for signal and encoder (PG) feed-
back lines.
The maximum length is 3 m (118.11 in) for reference input lines and is 20 m (787.40 in) for PG feedback lines.
• Do not touch the power terminals for five minutes after turning power OFF because high voltage may still
remain in the SERVOPACK.
Make sure the charge indicator is turned OFF first before starting an inspection.
• Avoid frequently turning power ON and OFF. Do not turn the power ON or OFF more than once per minute.
Since the SERVOPACK has a capacitor in the power supply, a high charging current flows for 0.2 seconds when the
power is turned ON. Frequently turning the power ON and OFF causes main power devices such as capacitors and
fuses to deteriorate, resulting in unexpected problems.
6.1.1 Names and Functions of Main Circuit Terminals
Terminal Symbol
L1,L2
∗1
L1,L2,L3
U,V,W
L1C,L2C
24V,0V
Name
Circuit
Voltage
Main circuit power
supply input terminal
Servomotor
connection terminals
Control circuit power
supply input terminal
Ground terminals
CAUTION
Main
Maximum
Applicable
Servomotor
(V)
Capacity
(kW)
100
0.03 to 0.2
Single-phase 100 to 115 VAC
200
0.03 to 0.4
Single-phase 200 to 230 VAC
200
0.5 to 7.5
Three-phase 200 to 230 VAC
400
0.5 to 3.0
Three-phase 380 to 480VAC
Connects to the servomotor.
100
0.03 to 0.2
Single-phase 100 to115 VAC
200
0.03 to 7.5
Single-phase 200 to 230 VAC
400
0.5 to 3.0
24 VDC (±15%)
Connects to the power supply ground terminals and
servomotor ground terminal.
6-2
Functions
+10%, -15%
(50/60 Hz)
+10%,-15%
(50/60 Hz)
+10%, -15%
(50/60 H)
+10%, -15%
(50/60 Hz)
+10%, -15%
(50/60 Hz)
+10%, -15%
(50/60 Hz)
∗2
∗2
∗2
∗2
∗2
∗2