II
Parameter
Encoder model
Signal period
Line count
Teach sequence
Display mode
Mechanical ratio
Reference marks
Analog filter frequency
Terminating resistor
94
Information for OEM and Setup users | Commissioning
Explanation
Connected encoder model
Settings:
Linear encoder: Linear axis
Angle encoder: Rotary axis
Angle encoder as linear encoder: Rotary axis is displayed as
linear axis
Default value: Depending on the connected encoder
For linear encoders
Length of a signal period
Setting range: 0.001 µm ... 1000000.000 µm
Default value: 20.000
For angle encoders and for display of a rotary axis as a linear axis.
Number of lines
Setting range: 1 ... 1000000
Default value: 1000
Starts the teach sequence for determining the Line count for an
angle encoder based on a specified angle of rotation.
For angle encoders and for the display of a rotary axis as a linear
axis.
Settings:
- ∞ ... ∞
0° ... 360°
-180° ... 180°
Default value: - ∞ ... ∞
For display of a rotary axis as a linear axis:
traverse path in mm per revolution
Setting range: 0.1 mm ... 1000 mm
Default value: 1.0
Configuration of the Reference marks
Further information: "Reference marks (Encoder)", Page 96
Frequency value of the analog low-pass filter
Settings:
33 kHz: Suppression of interference frequencies above 33 kHz
400 kHz: Suppression of interference frequencies above
400 kHz
Default value: 400 kHz
Dummy load to avoid reflections
Settings: ON or OFF
Default value: ON
HEIDENHAIN | POSITIP 8000 | Operating Instructions Turning | 03/2022