HEIDENHAIN POSITIP 8000 Series Operating Instructions Manual page 132

Digital readout
Table of Contents

Advertisement

II
Parameter
Spindle position
Enable spindle CCW
Spindle speed display via analog input (S)
Settings ► Axes ► S ► Inputs ► Spindle speed display via analog input
Parameter
Spindle speed display via analog
input
Input for spindle speed display
Spindle speed at input voltage 5
V
Adding Gear stages
Settings ► Axes ► S ► Gear stages ► +
Parameter
132
Information for OEM and Setup users | Commissioning
Explanation
Assignment of a digital input; if a spindle speed was set under
Maximum spindle speed for oriented spindle stop, the signal
switches the spindle to de-energized state upon stopping at a
defined position
Default value: Not connected
Assignment of a digital input for counterclockwise direction of
spindle rotation according to pin layout
Default value: Not connected
The external input signal takes precedence over
the direction of rotation set in the OEM bar or in the
Programming menu.
The external signal is only evaluated if a high level is
constantly present at the digital input for Spindle start.
Explanation
Activation of spindle-speed display in the position display
Settings: ON or OFF
Default value: OFF
Assignment of the analog input according to pin layout
Default value: Not connected
Entering the spindle speed at an input voltage of 5 V
Default value: 2000
The measured input voltage is offset against the factor
Spindle speed at input voltage 5 V. The result is
shown as actual speed in the position display.
Explanation
Adding a new gear stage with default name
HEIDENHAIN | POSITIP 8000 | Operating Instructions Turning | 03/2022