Information for OEM and Setup users | Commissioning
Movement commands from analog input
Settings ► Axes ► X, Y ... ► Inputs ► Movement commands from analog input 
Parameter
Enable analog movement
commands
Input for analog movement
commands
Dead band
Invert the analog input
Fmax
Fmax for smooth feed
Set input voltage
HEIDENHAIN | POSITIP 8000 | Operating Instructions Turning | 03/2022
Explanation
Enabling movement commands from external input devices (such
as a joystick) via the analog input
Settings: ON or OFF
Default value: OFF
Analog movement commands are only available if the
digital movement commands are deactivated.
Further information: "Movement commands from
digital input", Page 116
To be able to work with external movement
commands you have to configure the Input for analog
movement commands
Assignment of the analog input for the movement commands
according to pin layout. The analog voltage at these inputs must
be within a range of 0 V...5 V
Default value: Not connected
Enter the entire voltage range in percent. The Dead band defines
the input voltage range around the zero position at which the
supplied voltage is not yet interpreted as a movement command.
The value refers to the entire voltage range.
Setting range: 0 % ... 100 %
Default value: 10 %
If this function is active, the analog input is inverted. With an
inverted input, a higher input voltage leads to a feed rate in
negative direction. A lower input voltage results in a feed rate in
positive direction
Default value: Not active
Fmax defines the maximum feed rate of the axis that can be
reached via movement commands from the analog input
Setting range: 100 mm/min ... 2000 mm/min
Default value: 2000
Definition of the feed rate for a slower feed rate with a fully
deflected joystick
Setting range: 100 mm/min ... 2000 mm/min
Default value: 200
To be able to use the function, an input must be
assigned in Smooth feed selection for analog
movement commands
Further information: "Inputs (Switching functions)",
Page 120
Starts a teach sequence to determine the input voltage