Encoder diagnostics
The diagnostic function allows you to perform a basic functional check of the
encoders. For absolute encoders with EnDat interface, the messages from the
encoder and its functional reserves are displayed. For incremental encoders
with 1 V
or 11 µA
PP
fundamental functioning of the encoders. Based on this initial diagnostic option for
encoders, you can initiate further actions for more detailed testing or repair.
The PWT 101 or PWM 21 from HEIDENHAIN provides further inspection
and testing capabilities.
For more information, please refer to www.heidenhain.com.
8.6.1
Diagnostics for encoders with 1 V
For encoders with 1 V
encoder based on the signal amplitudes, asymmetry, and phase deviation. These
values are also displayed graphically as a Lissajous figure.
1 Lissajous figure
2 Amplitude A
3 Amplitude B
4 Asymmetry
5 Phase error
6 Amplitude tolerances
Settings ► Axes ► <Axis name> ► Encoder ► Diagnosis
HEIDENHAIN | POSITIP 8000 | Operating Instructions Turning | 03/2022
Tap File management in the main menu
Navigate to the list of storage locations
Tap Safely remove
The message "The storage medium can be removed now."
appears
Disconnect the USB mass storage device
interface, the displayed values allow you to evaluate the
PP
/11 µA
PP
/11 µA
interface, you can evaluate the functioning of the
PP
PP
interface