Information for OEM and Setup users | Commissioning
Parameter
Rounding method for angular
values
Decimal places for angular
values
Decimal separator
4.6
Configuring the axes
The procedure varies depending on the interface type of the connected encoder and
on the type of axis:
Encoders with EnDat interface:
The encoder applies the parameters automatically
Further information: "Configuring axes for encoders with EnDat interface",
Page 92
Encoders with 1 V
The parameters must be configured manually
Axis type Spindle, Gear spindle and Spindle with orientation
The inputs, outputs, and additional parameters must be configured manually
Further information: "Spindle axis S", Page 126
Axis type Axis + NC, Electronic handwheel (software option): The inputs,
outputs, and additional parameters must be configured manually
Further information: "Configuring specific settings for Axis + NC", Page 109
Further information: "Configuring an Electronic handwheel", Page 133
For the parameters of HEIDENHAIN encoders that are typically connected to the
product, refer to the overview of typical encoders.
Further information: "Overview of typical encoders", Page 91
HEIDENHAIN | POSITIP 8000 | Operating Instructions Turning | 03/2022
Explanation
Rounding method for decimal angular values
Settings:
Commercial: Decimal places from 1 to 4 are rounded down,
decimal places from 5 to 9 are rounded up
Round off: Decimal places from 1 to 9 are rounded down
Round up: Decimal places from 1 to 9 are rounded up
Truncate: Decimal places are truncated without rounding up or
down
Round to 0 and 5: Decimal places ≤ 24 or ≥ 75 are rounded to
0, decimal places ≥ 25 or ≤ 74 are rounded to 5
Default setting: Commercial
Number of decimal places for angular values
Setting range:
Radian: 0 ... 7
Decimal degrees: 0 ... 5
Deg-Min-Sec: 0 ... 2
Default value:
Radian: 5
Decimal degrees: 3
Deg-Min-Sec: 0
Separator for the display of values
Settings: Point or Comma
Default setting: Point