HEIDENHAIN POSITIP 8000 Series Operating Instructions Manual page 110

Digital readout
Table of Contents

Advertisement

II
Axis + NC
Depending on the configuration of the connected machine tool, you must configure
the inputs and outputs and further parameters of the NC axis prior to operation.
Settings ► Axes ► Axis name  
Parameter
Axis name
Axis type
Encoder
Error compensation
Outputs
Inputs
Software limit switches
Start-up time
Kv factor P
110
Information for OEM and Setup users | Commissioning
Explanation
Selecting the axis name displayed in the position preview
Default setting: Not defined
You can configure the following axes: X, Z, Zo, C, S.
The axis name S is displayed in the selection list once
you have selected Spindle, Gear spindle or Spindle
with orientation under Axis type.
Definition of the axis type
Settings:
Axis + NC (possible for up to three axes): NC-controlled linear
axis or rotary axis
Configuration of the connected encoder
Further information: "Overview of typical encoders", Page 91
Configuration of the linear error compensation LEC or segmented
linear error compensation SLEC
Further information: "Configuring linear error compensation
(LEC)", Page 99
Further information: "Configuring segmented linear error compen-
sation (SLEC)", Page 100
Configuration of the Outputs for the NC function
Further information: "Outputs", Page 112
Configuration of the Inputs for the NC function
Further information: "Inputs", Page 116
Configuration of the Software limit switches
Further information: "Software limit switches", Page 119
Configuration of the acceleration behavior and the braking behav-
ior of the axis; time during which the drive accelerates from stand-
still to maximum feed rate Fmax or decelerates from maximum
feed rate to standstill
Setting range: 50 ms ... 10000 ms
Default value: 500
Proportional component of the position controller during position-
ing; effective during axis traverse when the position is not being
approached or if the positioning window has not yet been reached
(moving over following error)
Setting range: 0.3 m/(min x mm) ... 6 m/(min x mm)
Default value: 2.5
HEIDENHAIN | POSITIP 8000 | Operating Instructions Turning | 03/2022