II
Configuring M functions
Settings ► Service ► OEM area ► Settings ► Program run ► M functions
Parameter
Number of the M function
Select image for dialog during
program run
Upload image file
Remove the entry
Configuring the central drive
Settings ► Service ► OEM area ► Settings ► Program run ► Central drive
Parameter
Axis
Select image for dialog during
program run
Upload image file
Remove the entry
4.8.6
Defining error messages
As an OEM, you can define specific error messages that either overwrite default
error messages or are triggered as additional messages through defined input
signals. For this purpose you can create a text database containing your specific
error messages.
148
Information for OEM and Setup users | Commissioning
Explanation
Enter the number of the new M function
Setting range: M2.0 ... M120.0 (0: The output assigned to the
M function is switched to inactive)
Setting range: M2.1 ... M120.1 (1: The output assigned to the
M function is switched to active)
Setting range: M2.2 ... M120.2 (2: The output assigned to the
M function generates a high active pulse of 8 ms)
Select the desired image for display during program run
Copies a selected image file to the storage location /Oem/Images
File format: PNG, JPG, PPM, BMP, or SVG
Image size: Max. 160 x 160 px
Remove the entry
Explanation
Axis name
Setting range: e.g. X, X+, X-
Only axes that have already been configured can be selected.
Select the desired image for display during program run
Copies a selected image file to the storage location /Oem/Images
File format: PNG, JPG, PPM, BMP, or SVG
Image size: Max. 160 x 160 px
Removing the entry