HEIDENHAIN POSITIP 8000 Series Operating Instructions Manual page 129

Digital readout
Table of Contents

Advertisement

Information for OEM and Setup users | Commissioning
Motor type: Unipolar servo motor
Settings ► Axes ► S ► Outputs
Parameter
Analog output
Analog output is inverted
Smax
Umax
Enable clockwise rotation
Enable counterclockwise
rotation
Drive enable
HEIDENHAIN | POSITIP 8000 | Operating Instructions Turning | 03/2022
Explanation
Assignment of the analog output according to pin layout
Default value: Not connected
If this function is active, the analog signal is inverted at the output
Default value: Not active
Definition of the Spindle speed attained at Umax
Setting range: 1 rpm ... 10000 rpm
Default value: 2000
Further information: "Special settings", Page 123
Maximum voltage that is output at the analog output in order to
attain Smax
Setting range: 1000 mV ... 10000 mV
Default value: 9000
Assignment of the digital output for the clockwise spindle enable
The input must be configured if the Unipolar servo motor motor
type is selected
Default value: Not connected
Assignment of the digital output for the clockwise spindle enable
The input must be configured if the Unipolar servo motor motor
type is selected
Default value: Not connected
Assignment of the digital output for the drive enable according to
pin layout
Default value: Not connected
II
129

Advertisement

Table of Contents
loading

Table of Contents