Information for OEM and Setup users | Commissioning
Motor type: Bipolar servo motor
Parameter
Analog output
Analog output is inverted
Open position control loop
Fmax
Umax
Drive enable
Target position reached
HEIDENHAIN | POSITIP 8000 | Operating Instructions Turning | 03/2022
Explanation
Assignment of the analog output of the servo motor according to
pin layout
Default value: Not connected
If this function is active, the analog signal is inverted at the output
Default value: Not active
If this function is active, the axis is operated with an open position
control loop
When you are setting up the product, you can move
the axes in an open position control loop. This way
you determine appropriate parameters for Fmax and
Umax.
Default value: Not active
Definition of the feed rate attained at Umax
Setting range: 100 mm/min ... 10000 mm/min
Default value: 2000
The Maximum machine speed cannot be exceeded,
even if you have defined a higher feed rate for
individual axes.
Further information: "Special settings", Page 123
Maximum voltage that is output at the analog output in order to
attain Fmax
Setting range: 1000 mV ... 10000 mV
Default value: 9000
Assignment of the digital output for the drive enable according to
pin layout
Default value: Not connected
Assignment of the digital output when the axis is on the Target
position in MDI mode or in program run
Default value: Not connected