HEIDENHAIN POSITIP 8000 Series Operating Instructions Manual page 188

Digital readout
Table of Contents

Advertisement

II
Parameter
Name
Switching function
Reference system
Axis
Switching point
Type of switching
Output
Output is inverted
Pulse
Pulse time
Lower limit
Upper limit
Remove the entry
188
Not all of the described parameters and options may be available,
depending on the product version, configuration and the connected
encoders.
Information for OEM and Setup users | Settings
Explanation
Name of the switching function
Selecting whether the switching function should be activated or
deactivated
Settings: ON or OFF
Default setting: ON
Selecting the desired reference system
Machine coordinate system
Preset
Target position
Tool tip
Selecting the desired axis
Selecting the axis position of the trigger point
Default setting: 0.0000
Selecting the desired type of switching
Edge from LOW to HIGH
Edge from HIGH to LOW
Interval from LOW to HIGH
Interval from HIGH to LOW
Default setting: Edge from LOW to HIGH
Selecting the desired output
X105.13 ... X105.16 (Dout 0, Dout 2, Dout 4, Dout 6)
X105.32 ... X105.35 (Dout 1, Dout 3, Dout 5, Dout 7)
X113.04 (Dout 0)
If the function is enabled, the output is set if the switching condi-
tion is not fulfilled or if the switching function is inactive
Default value: Not active
Selecting whether the pulse should be activated or deactivated
Settings: ON or OFF
Default setting: ON
Selecting the desired pulse length
0.1 s ... 999 s
Default setting: 0.0 s
Selecting the lower limit of the axis position at which switching is
to occur (only with Interval type of switching)
Selecting the upper limit of the axis position at which switching is
to occur (only Interval type of switching)
Removing the position-dependent switching function
HEIDENHAIN | POSITIP 8000 | Operating Instructions Turning | 03/2022