II
Switching functions
Settings ► Axes ► General settings ► Switching functions
Parameters
Inputs
Outputs
Inputs (Switching functions)
Settings ► Axes ► General settings ► Switching functions ► Inputs
Parameter
Control voltage on
Emergency stop active
Rapid traverse
120
The switching functions must not be used as a part of a safety function.
The switching functions must not be used as a part of a safety function.
Information for OEM and Setup users | Commissioning
Explanation
Assignment of the digital input for the respective switching
function according to the pin layout
Further information: "Inputs (Switching functions)", Page 120
Assignment of the digital output for the respective switching
function according to the pin layout
Further information: "Outputs (Switching functions)", Page 122
Explanation
Assignment of the digital input for querying the external control
voltage (e.g. for the machine to be controlled)
Default value: Not connected
Assignment of the digital input for querying whether an externally
connected emergency stop switch was activated
Default value: Not connected
Assignment of the digital input for a push button that activates
rapid traverse. The rapid traverse is active as long as the push
button is pressed and held.
If rapid traverse is activated, feed rate limitation is ignored by the
feed rate override and the axes traverse at rapid traverse.
Default value: Not connected
HEIDENHAIN | POSITIP 8000 | Operating Instructions Turning | 03/2022