B.5 FlexLoader conveyor system control
Overview
The FlexLoader Vision conveyor system control is structured according to the
following overviews.
These modules are part of the internal control system and must not be changed.
Module
FeedLine.mod
FeedLineInPosition.mod
FeedLineToFar.mod
FeedersSuperVision.mod
TpsView files
Product manual - FlexLoader Vision
3HAC051771-001 Revision: B
Description
Overall handling of conveyors and alarms connected to con-
veyor system.
Specialized task for handling start and stop of inconveyor
with short response time, regular operation with InPosi-
tion-sensor.
Specialized task for handling start and stop of inconveyor
with short response time, regular operation with ToFar-sensor.
Specialized task for checking if operator has manually oper-
ated any conveyor.
Optional files for control of conveyor system through the
FlexPendant.