A.2 Logging the operation
Logging of images while running
In some rare cases there may be a need to log images while running, for example
in the event of very infrequent faults. A special log window must be activated to
save each individual image to the hard disk during operation. This is done by first
clicking the Operation icon and then pressing Ctrl+L. The following window opens:
xx1800001067
To activate logging, select Log images and enter the search path to the location
where the images are to be saved. Then close the window and start operation in
the normal way.
The images are saved on a rolling basis with a maximum of 19,999 images. The
logging affects the cycle times, because saving to file takes time.
The image files are saved in the format CAMX_YYYYY.tif, where X is the camera
number (0 .. 3) and YYYYY is a serial number.
Operating with logged images (only 2D)
Images that were logged as above can then be used to run from file.
To run a detail with logged images, the detail must first be selected in the usual
way in the operating window. Then the special log window must be activated. This
is done by first clicking the Operation icon and then pressing Ctrl+L. Select Run
Product manual - FlexLoader Vision