9.3 Communication problems

FlexLoader Vision PLC
The alarm PLC could not be initialized is displayed at start up
FlexLoader Vision robot
FlexLoader Vision has no contact with the robot
Messages about missing robot signals
Messages about missing robot variables
Product manual - FlexLoader Vision
3HAC051771-001 Revision: B
Check that the PLC can be reached via the network: Run ping
192.168.125.151 (adjust the IP address to the relevant system settings) in a
command window. If the PLC does not respond, check the network wiring
and the switch.
In FlexLoader Vision ConfigurationEditor, check that the IP-address for the
PLC is correct.
Check that the robot can be reached via the network: Run ping 192.168.125.1
(adjust the IP address to the relevant system settings) in a command window.
If the robot does not respond, check the network wiring, switch and the
network settings of the robot.
Check that the robot has all necessary options and hardware installed to
communicate via the network.
Check that Windows firewall is configured correctly.
Check if the named signal is defined in the robot.
Check if the named variable is defined in the robot.
© Copyright 2014-2018 ABB. All rights reserved.
9 Troubleshooting
9.3 Communication problems
125