11 Commissioning
11.3.2 Settings
Continued
DHCP is used as standard setting.
Settings for Basler GigE cameras
Network setting for cameras
The following instructions assume that ABB's standard IP address settings are
used. The same steps must be followed if alternative IP addresses are to be used.
The only difference is in the addresses that must be entered.
Continues on next page
154
Note
The network configuration on the factory network can be freely adopted to the
customers network.
Note
Please refer to the section on cyber security in the robot integrator's guide for
additional information.
1 Connect the camera to the computer. Start Pylon IP Configuration Tool and
check that a connected camera can be seen. Select the camera.
xx1800000966
2 Select the radio buttons in the IP Configuration Protocol pane according to
the image below. Specify the correct Device User ID (Camera1, Camera2,
Camera3, Camera4 for the respective camera) and the correct data in the
Static IP address pane (Camera1 192.168.2.2, Camera2 192.168.2.3,
Camera3 192.168.2.4, Camera4 192.168.2.5, Subnet Mask 255.255.255.0,
GateWay 192.168.2.1) as below.