9 Troubleshooting
9.4 Camera problems
9.4 Camera problems
The system cannot connect to the camera
The camera image is far too light or too dark.
126
•
Check that the camera can be reached via the network: Run ping 192.168.2.2
(adjust the IP address to the relevant system settings and desired camera)
in a command window. If the camera does not respond, check the network
wiring, switch, and the network settings of the camera.
•
Check the lighting.
•
Go to the image settings and check the settings for contrast, brightness and
gain.
•
If the image is still too light or too dark, adjust the aperture. Do not forget to
recalibrate the robot and vision system when you have adjusted the camera.