Routine
FUNC num getAllowed-
NumberToStack()
PROC ValidateLight-
Branch()
Standardized sequences are used to load and unload details in the machine, using
the detail data from FlexLoader Vision. These sequences must be checked prior
to each commissioning.
The sequences are based on the machine being loaded from the front. If the
machine is loaded from above or if anything else is unusual, some adjustments
are required.
FeederOut.sys
The module FeederOut.sys provides routines for control of outconveyor and leave
pattern calculation.
Routine
FUNC pos CalcFeed-
erOutLeaveOffset(\inout
num presentLayer,\num
feederNo,\bool leftOver-
Part)
PROC CalibSpeedFeed-
erOut()
PROC ConfirmLeave-
FeederOut(\num feed-
erNo)
FUNC bool hasPermis-
sionToLeaveFeed-
erOut(\num feederNo)
Product manual - FlexLoader Vision
3HAC051771-001 Revision: B
Description
Returns allowed number of details to stack on outbelt
Add current branch to validated array.
LoadMachine_MAIN
LoadMachine_MAIN_UnLoad_SUB
LoadMachine_SUB
LoadMachine_SUB_UnLoad_MAIN
UnLoadMachine_MAIN
UnLoadMachine_SUB
UnloadMachine_MAIN_Load_MAIN
UnloadMachine_SUB_Load_SUB
UnloadMachine_LeftOverPart_MAIN
UnloadMachine_LeftOverPart_SUB
Description
This procedure is called from user program whenever a detail
should be placed on outconveyor.
User should use the returned offsets for the leave position when
leaving detail and then call ConfirmLeaveFeederOut when finished.
If no confirm, then robot will get the same leave offsets next time
this function is called.
If using SetUpFeederOutBelt the leave position pLeaveFeederOut
is forced to x,y,z = 0,0,0 in this function! Never change that position
name.
Help procedure for calibrating out belt speed
Call this to confirm that last detail has been placed at the last co-
ordinates that was given from CalcFeederOutLeaveOffset.
Number of parts left at feeder out is updated and belt is started if
current row is full.
This function checks if robot has permission to leave on feeder
out.
If selected, it will also check if feeder out has moved and in that
case re-initialize the feeder.
© Copyright 2014-2018 ABB. All rights reserved.