11 Commissioning
11.3.4 Configuration of user-defined mechanical equipment
Continued
User-defined inputs
PLC inputs that are to be shown for the user are defined here. There are up to 16
user-defined inputs, which can be freely defined. These are used to show the status
of the equipment in FlexLoader Vision. Inputs can also be defined as memory bits
or datablock memories (datablock 1) in the PLC.
Parameter
Name
DataBlock
Byte
Bit
DataType
xx1800000987
User-defined outputs
PLC outputs that are to be shown for the user are defined here. There are up to
16 user-defined outputs, which can be freely defined. These are used to show the
status of the equipment in FlexLoader Vision.
Parameter
Name
DataBlock
Byte
Bit
DataType
xx1800000988
Continues on next page
162
Description
Text that appears on FlexLoader Vision's user interface. Enter NONE if
the input is not used.
If DataType is set to 2 (ByteBits) the number of the datablock is specified
here.
Byte for the physical input.
Bit for the physical input.
Determines whether FlexLoader Vision is to write actual PLC inputs (0),
memory addresses in PLC (1) or datablock memories in PLC (2).
Description
Text that appears on FlexLoader Vision's user interface. Enter NONE if
the output is not used
If DataType is set to 2 (ByteBits) the number of the datablock is specified
here.
Byte for the physical input.
Bit for the physical input.
Determines whether FlexLoader Vision is to write actual PLC outputs
(0), memory addresses in PLC (1) or datablock memories in PLC (2).
© Copyright 2014-2018 ABB. All rights reserved.
Product manual - FlexLoader Vision
3HAC051771-001 Revision: B