9 Troubleshooting

9.2 Identification problems

9.2 Identification problems
FlexLoader Vision does not find any details
FlexLoader Vision identifies an incorrect position
124
During operation: Check that the correct detail is selected.
During teachin: If the detail is too light or shiny it can be difficult for the system
to discern the detail from a conveyor that is light in color. This can result in
no detail being found. The same problem can occur with a dark detail and a
black conveyor. To test if the detail is too light, a matt black disc or similar
can be placed temporarily underneath the camera and a new teachin carried
out. If this works, the problem can be solved by changing to a dark conveyor.
Note that the operation of previous teachin details may be affected by the
new conveyor color.
Redefine the masked surface. Try to find an identification surface of the
present position that markedly differs from other positions.
© Copyright 2014-2018 ABB. All rights reserved.