9 Troubleshooting
9.2 Identification problems
9.2 Identification problems
FlexLoader Vision does not find any details
FlexLoader Vision identifies an incorrect position
124
•
During operation: Check that the correct detail is selected.
•
During teachin: If the detail is too light or shiny it can be difficult for the system
to discern the detail from a conveyor that is light in color. This can result in
no detail being found. The same problem can occur with a dark detail and a
black conveyor. To test if the detail is too light, a matt black disc or similar
can be placed temporarily underneath the camera and a new teachin carried
out. If this works, the problem can be solved by changing to a dark conveyor.
Note that the operation of previous teachin details may be affected by the
new conveyor color.
•
Redefine the masked surface. Try to find an identification surface of the
present position that markedly differs from other positions.
© Copyright 2014-2018 ABB. All rights reserved.
Product manual - FlexLoader Vision
3HAC051771-001 Revision: B