Error management
Errors are read as single bits from up to four word memories in PLC. It is possible
to select whether the alarm for each word memory is to be camera specific or not.
If they are camera specific, the text camera X appears in the alarm text. Also note
that in a Siemens PLC, a byte swap occurs, which means that the start address
for the word in the PLC corresponds to ErrorDescription 9. Other bytes in the PLC
word memory start at ErrorDescription 1.
Parameter
AddressErrorWord1
AddressError-
Word2,3,4
ErrorDescriptionX
xx1800000985
Product manual - FlexLoader Vision
3HAC051771-001 Revision: B
11.3.4 Configuration of user-defined mechanical equipment
Description
Enter memory location for error messages 1–16. Enter 0 if this ad-
dress is not to be used.
As above, but for error messages 17–32, 33–48, 49–64.
Text that is shown if corresponding bit in corresponding AddressEr-
rorWord is 1.