General control bits
PLC cursors that are to be shown for the user are defined here. There are up to 8
user-defined cursors, which can be freely defined. These are used to allow manual
control of the equipment from FlexLoader Vision.
Parameter
Name
DataBlock
Memory
Bit
DataType
RobotID
xx1800000989
Start, stop and reset bit
PLC markers that are used at start and stop in FlexLoader Vision are defined here.
These are used to synchronize the equipment with FlexLoader Vision.
The PLC marker is set to 1 for 0.5 s at start, stop or reset
Note that you can use dual reset bits. Both ResetBit and ResetBit2 are available.
This may be useful if reset needs to be sent to both the robot and the PLC.
Parameter
Name
DataBlock
Memory
Bit
DataType
RobotID
Product manual - FlexLoader Vision
3HAC051771-001 Revision: B
11.3.4 Configuration of user-defined mechanical equipment
Description
Text that appears on FlexLoader Vision's user interface. Enter NONE if
the function is not used
If DataType is set to 1 (ByteBits) the number of the datablock is specified
here.
Address for the physical input.
Bit for the physical input.
Determines whether FlexLoader Vision is to write memory addresses in
PLC (0), datablock memories in PLC (1) or actual PLC outputs (2).
Indicates the name of a robot variable that the value is written to.
Description
Text that appears on FlexLoader Vision's user interface. Enter NONE if
the function is not used
If DataType is set to 1 (ByteBits) the number of the datablock is specified
here.
Address for the physical input.
Bit for the physical input.
Determines whether FlexLoader Vision is to write memory addresses in
PLC (0), datablock memories in PLC (1) or actual PLC outputs (2).
Indicates the name of a robot variable that the value is written to.
© Copyright 2014-2018 ABB. All rights reserved.
11 Commissioning
Continued
Continues on next page