F FlexLoader RAPID reference
F.5 FlexLoader conveyor system control
F.5 FlexLoader conveyor system control
Overview
The FlexLoader SC 6000 conveyor system control is structured according to the
following overviews.
These modules are part of the internal control system and must not be changed.
Module
FeedLine.mod
FeedLineInPosition.mod
FeedLineToFar.mod
FeedersSuperVision.mod
TpsView files
210
Description
Overall handling of conveyors and alarms connected to con-
veyor system. This module is loaded into a separate back-
ground task.
Specialized task for handling start and stop of inconveyor
with short response time, regular operation with InPosi-
tion-sensor. This module is loaded into a separate background
task.
Specialized task for handling start and stop of inconveyor
with short response time, regular operation with ToFar-sensor.
This module is loaded into a separate background task.
Specialized task for checking if operator has manually oper-
ated any conveyor. This module is loaded into a separate
background task.
Optional files for control of conveyor system through the
FlexPendant.