Interfaces

3.2 Activation via F-DI

3.2
Activation via F-DI
3.2.1

Fail-safe digital inputs

In the factory setting of the inverter, the fail-safe digital inputs are not assigned to the
integrated safety functions. It is only at the parameterization stage that you define, for
example, whether digital inputs DI4 and DI5 are to be used for standard functions or whether
a fail-safe dual-channel input is to be created by merging.
Assignment of the fail-safe digital inputs
Table 3- 1
Terminal strip
Terminal 16
Terminal 17
Table 3- 2
Terminal strip
Terminal 5
Terminal 6
Terminal 7
Terminal 8
Terminal 16
Terminal 17
Safety-related signals, e.g. the switching state of a sensor, must be wired on two channels
with a fail-safe digital input. The inverter evaluates the signal on two separate signal paths.
76
SINAMICS G120C and for SINAMICS G120 with Control Units CU240E-2 and CU240E-
2 DP
Digital input
DI 4
DI 5
SINAMICS G120 with Control Units CU240E-2 F and CU240E-2 DP-F
Digital input
DI 0
DI 1
DI 2
DI 3
DI 4
DI 5
Fail-safe digital input
F-DI 0
Fail-safe digital inputs
Basic Safety
-
F-DI 0
Safety Integrated Function Manual, SINAMICS G120 and G120C
Function Manual, 01/2011, FW 4.4, A5E03052391B AB
Extended Safety
F-DI 0
F-DI 1
F-DI 2