General Purpose Relay

Description
The system allows up to eight general purpose relays using PGD(2)-U10 ADP's (four
relays per PGD unit) and one general purpose relay built into the GCD-CP10 for a
maximum of nine relays. These relays are normally opened and can be closed by
dialing an access code on any terminal or pressing a preprogrammed function key on
any multiline terminal.
The relays can then be set back to an open state by dialing an access code on any
terminal or by pressing a preprogrammed function key on any multiline terminal. A
relay can also be set back to an open state after a drive timer expires. Each relay
can have a separate drive timer, when the relay is in a closed state, and this timer
expires, the relay is automatically placed back into an open state.
Conditions
When relays 5 & 6 of a PGD(2)-U10 are assigned as General Purpose
Relays, they cannot be used for Door Box/Page Relays. Therefore it is
recommended to first use
function allowing relays 5 & 6 to be used for Door Box/Page Relays.
All General Purpose Relays can be programmed with a drive timer. The
drive timer allows the relay to return to the normally opened position
after a timer expires not requiring a user to dial a service code or press
a line key to set the relay back to the open position.
The drive timer on a General Purpose Relay can be bypassed by
dialing an access code on any terminal or pressing a preprogrammed
line key on any multi line terminal.
Multiline telephones can activate the General Purpose Relay while in a
talking state (call must be answered not just a voice announce) by
pressing a preprogrammed line key. All other terminal types cannot
activate the relay while a call is in progress.
The General Purpose Relay cannot be activated by DISA.
Default Settings
Disabled
System Availability
General Purpose Relay Specifications
Contact Configuration
Maximum Load
Maximum Initial Contact Resistance
relays 7 & 8 for General Purpose Relay
Normally Open
500mA @24 VDC
50m Ohms