Program
Program Name/Description
Number
DTMF Tone Receiver Setup – Max. Detect
80-03-04
Level
Define the maximum detection level for DTMF
Tone Receiver.
DTMF Tone Receiver Setup – Forward Twist
80-03-05
Level
Define the forward twist level for DTMF Tone
Receiver.
Input Data
0 ~ 15
detect level 0:
0dBm(0) to -15dBm(15)
detect level 1:
-5dBm(0) to -20dBm(15)
detect level 2:
-10dBm(0) to -25dBm(15)
detect level 3:
-15dBm(0) to -30dBm(15)
detect level 4:
-20dBm(0) to -35dBm(15)
detect level 5:
-25dBm(0) to -40dBm(15)
detect level 6:
-30dBm(0) to -45dBm(15)
detect level 7:
-35dBm(0) to -50dBm(15)
detect level 8:
-40dBm(0) to -55dBm(15)
detect level 9:
-45dBm(0) to -60dBm(15)
detect level 10:
-50dBm(0) to -65dBm(15)
detect level 11:
-55dBm(0) to -70dBm(15)
detect level 12:
-60dBm(0) to -75dBm(15)
detect level 13:
-65dBm(0) to -80dBm(15)
detect level 14:
-70dBm(0) to -85dBm(15)
detect level 15:
-75dBm(0) to -90dBm(15)
0 ~ 9
(1dB ~ 10dB)
79
Default
Type 1 ~ 5 = 2
(-2dBm)
Type 1 = 5
(6dBm)
Type 2 = 5
(6dBm)
Type 3 = 5
(6dBm)
Type 4 = 5
(6dBm)
Type 5 = 5
(6dBm)