Program
Program Name/Description
Number
Speed Dialing Number and Name – Transfer
13-04-04
Destination Number
When the incoming caller ID matches the
number programmed in the speed dial bin, this
setting determines the destination of the call.
Speed Dialing Number and Name –
13-04-05
Incoming Ring Pattern
Define the ring tone for the caller ID routed call.
Basic Trunk Data Setup – Caller ID Refuse
14-01-27
Setup
Define if the trunk will reject the call by playing
the VRS message based on the Caller ID
information.
15-07-01
Programmable Function Keys
Assign function key 86 (Set Private Call
Refuse) to Enable/Disable trunks which are set
in Program 14-01-27 to "1".
Assign function key 87 (Set Caller ID Refuse) to
Enable/Disable the Caller ID Refusal (trunks)
which is set in Program 14-01-27 to "1".
20-07-24
Class of Service Options (Administrator
Level) – Set/Cancel Private Call Refuse
Enable (1) or Disable (0) an extension user
ability to set or cancel Private Call Refuse.
20-07-25
Class of Service Options (Administrator
Level) – Set/Cancel Caller ID Refuse
Enable/Disable an extension ability to set or
cancel Caller ID Refuse.
Voice Announcement Service Option – Set
40-10-06
VRS Message for Private Call Refuse (VRS
Msg Private Call)
Assign the VRS Message number used as
Private Call Refuse. When Fixed message is
set, VRS message guidance is: Service
finished. Disconnect the line, please.
Input Data
If Transfer mode is (Refer to
13-04-03):
1 = Internal Dial Mode
#
1 ~ 9, 0,
*
,
, P, R, @
(Maximum 24 Characters)
2 = Incoming Ring Group
0 ~ 100 (IRG Number)
P = Pause R = Recall
@ = Additional Digits when
using ISDN functionality
Incoming Ring Pattern
0 = Normal Pattern
1 ~ 4 = Tone Pattern (1 ~ 4)
5 ~ 9 = Scale Pattern (1 ~ 5)
10 ~ 13 = Tone Patterns (5 ~ 8)
0 = Disable (No)
1 = Internal Dial
2 = Enable (Yes)
Line Key 1 ~ 48
0 ~ 99 (Normal Function Code
851 by default)
*
*
00 ~
99 (Appearance
Function Code) (Service Code
852 by default)
0 = Off
1 = On
0 = Off
1 = On
0 ~ 101
(0 = No message) (101
= Fixed message)
121
Default
No Setting
0
0
COS 1 ~ 15 = 0
COS 1 ~ 15 = 0
0