NEC UNIVERGE SV9100 Features And Specifications page 479

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

Guide to Feature Programming
Program
Program Name/Description
Number
Service Code Setup (for Service Access) –
11-12-42
Flash on Trunk Lines
Customize the Service Codes for flash on trunk
lines.
Analog Trunk Data Setup – Flash Type
14-02-03
Make sure this item is set for open loop Flash.
Analog Trunk Data Setup – Hooking Type
14-02-04
For each trunk, select Timed Flash or open loop
Disconnect.
14-04-01
Behind PBX Setup
For each trunk, indicate if the trunk is installed
behind a PBX.
Multiline Telephone Basic Data Setup –
15-02-05
Transfer Key Operation Mode
For the Cordless Lite/Cordless Lite II telephone
user to use the flash function, this option must
be set to 2. This changes the Transfer key to a
Flash key.
Single Line Telephone Basic Data Setup –
15-03-04
Flashing
Enable/Disable Flash for single line (500/2500
type) telephones.
Input Data
SLT
*
#
0 ~ 9,
,
Maximum of eight
digits
0 = Open Loop Flash
1 = Ground
0 = Timed Flash (Hooking)
1 = Disconnect (Cut)
0 = Stand Alone (Trunk)
1 = Behind PBX (PBX)
2 = Not Used
3 = CTX assume 9
0 = Transfer
1 = Serial Call
2 = Flash
0 = No
1 = Yes
479
Default
#
3
0
0
0
0
1

Advertisement

Table of Contents
loading