NEC UNIVERGE SV9100 Features And Specifications page 941

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

Guide to Feature Programming
Refer to
Single Line Telephones
Program
Program Name/Description
Number
10-03-01
ETU Setup
Set up and confirm the basic configuration data
for each blade. This program represents
different data depending on the blade installed
in the slot.
10-09-01
DTMF and Dial Tone Circuit Setup
Allocate the circuits on the GCD-CP10 ETUs
for either DTMF receiving or dial tone detection.
Program 14-01-13 Basic Trunk Data Setup –
Loop Supervision Enable (1) loop supervision
for each trunk that should be able to use Call
Forwarding – Centrex.
Single Line Telephone Basic Data Setup –
15-03-01
SLT Signaling Type
Select the type of dialing the connected
telephone uses.
For the UNIVERGE SV9100 Wireless
telephones to function correctly, this must be
set to 0. If this option is set for DTMF, after an
outside call is placed, the system cannot dial
any additional digit.
This program change is automatically
performed when the UNIVERGE SV9100
Wireless telephone is registered. When
upgrading software from prior versions, the
previous default of 1 is saved from the prior
database so this option must be changed
manually.
related programming.
The assigned data varies
depending on the blade installed
in the slot.
0 = Common Use
1 = Extension Only
2 = Trunk Only
0 = DP
1 = DTMF
941
Input Data
.
Circuit/Resource
01 ~ 08 = 1
(Extensions)
Circuit/Resource
09 ~ 32 = 2
(Trunks)
Circuit/Resource
33 ~ 144 = 0
(Common)
When
GPZ-BS10 is
installed, 81 ~
144 are available
Default
1