NEC UNIVERGE SV9100 Features And Specifications page 508

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

Program
Program Name/Description
Number
Timer Class Timer Assignment – Intercom
20-31-04
Interdigits Time (Intercom I/D Timer)
When placing Intercom calls, extension users
must dial each digit during this time.
Timer Class Timer Assignment – Trunk
20-31-05
Interdigits Time (Trunk I/D Timer)
The system waits for this time to expire before
placing the call in a talk state (Call Timer starts
after time expires, Voice Over and Barge-In are
not allowed until after time expires).
Timer Class Timer Assignment – Hotline
20-31-06
Time Start Time (Hotline Start)
A Ringdown extension automatically calls its
programmed destination after this time.
Timer Class Timer Assignment – Ring No
20-31-07
Answer Alarm Time
If a trunk rings a multiline telephone longer than
this time, the system changes the ring cadence.
This indicates to the user that the call has been
ringing too long.
Timer Class Timer Assignment – DIL/
20-31-08
Incoming Ring Group No Answer Time
A DIL that rings its programmed destination
longer than this time diverts to the DIL No
Answer Ring Group (set in Program 22-08).
Timer Class Timer Assignment – DID Ring-
20-31-09
No-Answer Time
In systems with DID Ring-No-Answer Intercept,
this time sets the Ring-No-Answer time. This is
the time a DID call rings the destination
extension before rerouting to the intercept ring
group.
Timer Class Timer Assignment – Hold
20-31-10
Recall Time (Non Exclusive Hold)
A call on Hold recalls the extension that placed
it on Hold after this time. This time works with
the Hold Recall Callback Time (Program
24-01-02).
Timer Class Timer Assignment – Hold
20-31-11
Recall CallBack Time (Non Exclusive Hold)
A trunk recalling from Hold or Park rings an
extension for this time. This time works with
Hold Recall Time or Park Hold Time. After this
time, the system invokes the Hold Recall Time
again. Cycling between time Program 24-01-01
and 24-01-02 and Program 24-01-06 and
24-01-07 continues until a user answers the
call.
Input Data
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
508
Default
10
5
5
60
0
20
90
30

Advertisement