NEC UNIVERGE SV9100 Features And Specifications page 176

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

Program
Program Name/Description
Number
20-13-16
Class of Service Options (Supplementary
Service) – Barge-In, Receive
Turn Off or On an extension user ability to
Barge-In at the receiving extension
(i.e., Barge-In receive).
This setting must be Enabled (1) for the Contact
Centre Call Monitoring Enhancement to
function.
20-13-17
Class of Service Options (Supplementary
Service) – Barge-In Tone/Display (Intrusion
Tone)
Turn Off or On the Barge-In (Intrusion) Tone. If
disabled, this also turns off the Barge-In display
at the called extension.
20-13-32
Class of Service Options (Supplementary
Service) – Deny Multiple Barge-Ins
Allow (1)/Deny (0) the extension user ability to
have multiple users Barge-In to their
conversation.
20-13-45
Class of Service Options (Supplementary
Service) – MIC Key Mode While Call
Monitoring
Set per class of service, when in Call
Monitoring Mode determines if the monitored
parties receives the barge in alert tone when
Coaching Mode is enabled.
Class of Service Options for DISA/E&M –
20-14-11
DISA/Tie Trunk Barge-In
Enable (1)/Disable (0) a DISA or tie trunk user
from using the Barge-In feature.
Operator Extension – Operator's Extension
20-17-01
Number
Define the extension numbers which are to be
used by operators.
Extensions defined in this program cannot be
monitored using the Call Enhancement feature.
Service Tone Timers – Intrusion Tone
20-18-07
Repeat Time
After a user Barges In, the system repeats the
Barge-In tone after this time. Normally, you
should disable this time by entering 0. (This
time also affects any other type of call
interruption features, such as Voice Mail
Conversation Recording, Voice Over, etc.)
System Options for Outgoing Calls – Trunk
21-01-03
Interdigit Time (External)
Program the time an extension must wait
before using the Barge-In feature can be used
on a call (this time expires before a call is put in
a talk state). This time also affects Voice Over.
Input Data
0 = Off
1 = On
0 = Off
1 = On
0 = Off
1 = On
0 = Enable
1 = Disable
0 = Off
1 = On
Maximum of eight digits
0 ~ 64800 seconds
0 ~ 64800 seconds
176
Default
COS 1 ~ 15 = 0
COS 1 ~ 15 = 1
COS 1 ~ 15 = 0
COS 1 ~ 15 = 1
COS 1 ~ 15 = 0
101
0
5

Advertisement

Table of Contents
loading

Table of Contents