When a message is received, the message icon is displayed.
Synchronous Ringing does not apply to the cordless terminals.
A beep indicates when the cordless terminal receives off-hook ringing.
A spare battery is available as an Optional Available Part. A second battery is not shipped
with the product.
The battery can be charged when it is installed in the handset or in the base charging unit
and the handset is in the charger. A stand-alone battery charger is not available.
Environments with many metal parts, metal shelves, or metal buildings are known to reduce
telephone performance.
When multiple cordless telephones are used in your office, they must operate on different
channels and be at least 20 feet apart (including the base unit and the telephones).
DECT telephones do not ring when receiving a doorbox call. Notification is shown in the
display.
Cordless DECT telephones can activate the door strike relay using a Recall key assigned in
the phone configuration or, by a Flash Key assigned to one of the line keys in Program
15-07 (851: 62).
Under certain conditions, HOLD and TRANSFER have the same behavior. To prevent an
unwanted transfer after placing a call on hold and calling another user, the Line Key for the
call on hold must be pressed to retrieve the call from hold, otherwise the call is transferred
when the Cordless Terminal is placed in idle.
The DTL-8R-1 DECT Cordless – only supports connection with DT400/DT300 terminals.
DTH-4R-1/2 Cordless is not supported on the SV9100.
Restrictions
Cordless terminals cannot receive voice announcements when idle.
Default Settings
None
System Availability
Terminals
DTL-8R-1 TEL
Required Component(s)
GCD-8DLCA Blade with GPZ-8DLCB Daughter Board
GCD-CP10 with GPZ-IPLE Daughter board
SIP telephone licenses
-OR-