NEC UNIVERGE SV9100 Features And Specifications page 842

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

Related Features
Central Office Calls, Answering
Central Office Calls, Placing
Direct Inward System Access (DISA)
Multiple Trunk Types
Warning Tone for Long Conversation
Guide to Feature Programming
Program
Program Name/Description
Number
Basic Trunk Data Setup – Long
14-01-14
Conversation Cutoff
Enable/Disable a trunk ability to disconnect
incoming and outgoing central office calls
automatically.
Basic Trunk Data Setup – Long
14-01-15
Conversation Alarm Before Cut Off
Enable/Disable the Long Conversation Alarm
for each trunk.
20-06-01
Class of Service for Extensions
Assign a Class of Service (1 ~ 15) to
extensions.
20-13-02
Class of Service Options (Supplementary
Service) – Long Conversation Cutoff
(Incoming)
Turn Off or On an extension user ability to use
Long Conversation Cutoff for incoming calls.
20-13-03
Class of Service Options (Supplementary
Service) – Long Conversation Cutoff
(Outgoing)
Turn Off or On an extension user ability to use
Long Conversation Cutoff for outgoing calls.
System Options for Long Conversation –
20-21-03
Long Conversation Cutoff for Incoming Call
Enter the time the system waits before
disconnecting incoming trunks.
System Options for Long Conversation –
20-21-04
Long Conversation Cutoff for Outgoing Call
Enter the time the system waits before
disconnecting outgoing trunks.
Operation
This feature is automatic once it is programmed.
Input Data
0 = Disable
1 = Enable
0 = Disable
1 = Enable
Day Night/Mode: 1 ~ 8
Class of Service of Extensions
(1 ~ 15)
0 = Off
1 = On
0 = Off
1 = On
0 ~ 64800 seconds
0 ~ 64800 seconds
842
Default
0
0
Extension port
101 = Class 15
All other
extension port =
Class 1
COS 1 ~ 15 = 0
COS 1 ~ 15 = 0
0
0