NEC UNIVERGE SV9100 Features And Specifications page 471

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

Guide to Feature Programming
Program
Program Name/Description
Number
Service Code Setup (for Service Access) –
11-12-56
E911 Alarm Shut Off
Select the Service Code (normally 786) that an
extension user can dial to shut off the E911
Alarm Ring.
Trunk Group – Trunk Group Number
14-05-01
Assign the outbound trunks you want to use for
E911 service to the same Trunk Group.
Trunk Group Routing – Priority Order
14-06-01
Number
Set the priority order number 1 ~ 4.
Input Data
MLT
*
#
0 ~ 9,
,
Maximum of eight
digits
Trunk Port 1 ~ 400 =
Priority 1 ~ 400
0 = Not Set
001 ~ 100 = Trunk group No.
101 ~ 150 = 100 + Networking
System No.
1001 ~ 1100 = 1000 + Route
Table No.
471
Default
786
Default = Trunks
1 ~ 400 assigned
to trunk group 1
with priorities
equal to the
trunk number.
Trunk 1 = Priority
1 Trunk 400 =
Priority 400.
Route 1, Order
Number 1 = 1
(Trunk Group 1)
Order Numbers
2, 3, 4 = 0 (Not
Specified)
All Other Routes
(2 ~ 100) and
Order Numbers
(1 ~ 4) = 0 (Not
Specified).