NEC UNIVERGE SV9100 Features And Specifications page 906

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

Program
Program Name/Description
Number
DTMF Tone Receiver Setup – OFF Detect
80-03-08
Time
Define the Off detection time for DTMF Tone
Receiver.
Call Progress Tone Detector Setup –
80-04-01
Detection Level
Define the detection levels for the Call Progress
Tone Detector.
Call Progress Tone Detector Setup – Min.
80-04-02
Detection Level
Define the minimum detection levels for the Call
Progress Tone Detector.
Call Progress Tone Detector Setup – S/N
80-04-03
Ratio
Define the S/N ratio for the Call Progress Tone
Detector.
Call Progress Tone Detector Setup – No
80-04-04
Tone Time
Define the no tone time for the Call Progress
Tone Detector.
Call Progress Tone Detector Setup – Pulse
80-04-05
Count
Define the pulse count for the Call Progress
Tone Detector.
Input Data
1 ~ 255
(15+ 15ms ~ 3825ms)
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
0 ~ 15
detect level 0:
-15dBm (0) to -30dBm(15)
detect level 1:
-30dBm (0) to -45dBm(15)
detect level 2:
-40dBm (0) to -55dBm(15)
0 ~ 4 (0dB ~ -20dB)
0 ~ 255 (30 + 30 ~ 7680ms)
(0 = not detect)
1 ~ 255 = 60 ~ 7680ms
The formula is 30 + 30N. When
set to N = 1, it means 30
+ 30 * 1 = 60.
When set to N=255, it means
30+30*255=7680
1 ~ 255
906
Default
Type 1 ~ 5 = 1
(30ms)
Type 1 (DT) – 0
(-25dBm)
Type 2 (BT) – 0
(-25dBm)
Type 3 (RBT) – 0
(-25dBm)
Type 4, Type 5 –
0
Type 1 (DT) – 15
(-25dBm)
Type 2 (BT) – 15
(-25dBm)
Type 3 (RBT) –
15
(-25dBm)
Type 4, Type 5 –
0
Type 1 (DT) – 4
(-20dB)
Type 2 (BT) – 4
(-20dB)
Type 3 (RBT) – 4
(-20dB)
Type 4, Type 5 –
0
Type 1 (DT) –
132 (3990ms)
Type 2 (BT) –
132 (3990ms)
Type 3 (RBT) –
132 (3990ms)
Type 4, Type 5 –
0
Type 1 (DT) – 1
Type 2 (BT) – 1
Type 3 (RBT) – 1
Type 4, Type 5 –
0