NEC UNIVERGE SV9100 Features And Specifications page 897

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

Program
Program Name/Description
Number
Trunk Group – Trunk Group Number
14-05-01
Assign trunks to Trunk Groups. You can also
assign the outbound priority for trunks in the
group. When users dial the trunk group, they
seize the trunks in the order you specify in the
outbound priority entry.
22-02-01
Incoming Call Trunk Setup
For each Night Service mode, enter service
type for each trunk.
COT Initial Data Setup – DP Interdigit Time
81-10-01
Selection
Select the DP Interdigit Time (minimum pause
time between Dial Pulses).
COT Initial Data Setup – Prepause Time
81-10-02
Selection
Specify the loop open time for a hookflash
signal sent to the CO or PBX when Recall on a
multiline terminal is pressed. A single line
telephone generates a hookflash to the CO or
PBX line when a single line telephone
hookflash is assigned.
COT Initial Data Setup – Incoming Signal
81-10-03
Detect Time Selection
Specify the time after the incoming signal from
another system is detected before the
acknowledge signal is sent out.
COT Initial Data Setup – Disconnect
81-10-04
Recognition Time Selection
Specify the minimum time before a
disconnected circuit can be accessed again.
COT Initial Data Setup – Auto Release Signal
81-10-05
Detection Time
Specify the signal detection time for release of a
CO/PBX line after a disconnect signal is
received from the distant Central Office or PBX.
Input Data
Trunk Port 1 ~ 400 =
Priority 1 ~ 400
0 = Normal
1 = VRS (second dial tone if no
VRS installed)
2 = DISA
3 = DID
4 = DIL
5 = E&M Tie line
6 = Delayed VRS
7 = ANI/DNIS
8 = DID(DDI) Mode Switching
0 = Pattern A
(Pattern A: 10pps – 650ms,
20pps – 500ms)
1 = Pattern B
(Pattern B: 10pps – 800ms,
20pps – 800ms)
1 ~ 13
(1 ~ 13 seconds)
(0 = No Setting)
0 ~ 15
(50 ~ 800ms)
1 ~ 15
(100ms ~ 1.5 seconds)
(0 = No Setting)
1 ~ 14
(50 ~ 700ms)
15 = (No limit)
(0 = No Setting)
897
Default
Default = Trunks
1 ~ 400 assigned
to trunk group 1
with priorities
equal to the
trunk number.
Trunk 1 = Priority
1 Trunk 400 =
Priority 400.
0
1 (Pattern B)
1 second
3 (200ms)
3 (300ms)
7 (350ms)

Advertisement