Table 17.3 A/D Conversion Time (Single Mode)

Item
Symbol Min Typ Max
A/D conversion
t
D
start delay
Input sampling
t
SPL
time
A/D conversion
t
CONV
time
Note: All values represent the number of states.

Table 17.4 A/D Conversion Time (Scan Mode)

CKS1
0
1
Rev. 1.0, 09/02, page 436 of 568
CKS1 = 0
CKS0 = 0
18
33
127 
515 
530
CKS0
0
1
0
1
CKS0 = 1
Min Typ Max
Min Typ Max
10
17
6
63
259 
131 
266
Conversion Time (State)
512 (Fixed)
256 (Fixed)
128 (Fixed)
64 (Fixed)
CKS1 = 1
CKS0 = 0
CKS0 = 1
Min Typ Max
9
4
31
15
134
67
5
68