No Monitor Session - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Parameter
ip-acl
acl-id
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 42)".
If you do not select any parameters from the parameter list, the default value (both) is used.
Result
The source for the mirroring of a port is deleted.
Further notes
You configure the source for mirroring a port with the
You end and delete a session with the
You display the configuration settings with the
12.4.2.9

no monitor session

Description
With this command, you delete the monitor session.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no monitor session<session-id(1-7)>
The parameter has the following meaning:
Parameter
session-id
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
Description
Keyword for an IP access control list
Number of the Access Control List
no monitor session
show monitor session
Description
Number of the session
7 parallel sessions are possible only
with port-based mirroring and their
ports must not overlap.
12.4 Port Mirroring
Range of values / note
-
-
monitor session ... source
command.
command.
Range of values / note
1 ... 7
Diagnostics
command.
933

Advertisement

Table of Contents
loading

Table of Contents