Result
The setting deciding which messages of the device are not stored or forwarded is
configured.
Further notes
You display the status of the events and the clients with the
You configure which of the various message types of the device will be stored or forwarded
with the
12.1.6.6

severity

Description
With this command, you configure the threshold values for the sending of system event
notifications.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli (config-events) #
Syntax
Call up the command with the following parameters:
severity { mail | log | syslog } { info | warning | critical }
The parameters have the following meaning:
Parameter
mail
log
syslog
info
warning
critical
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
command.
event config
Description
Specifies the threshold value for send-
ing system event messages by e-mail.
Specifies the threshold value for enter-
ing system event messages in the log
table.
Specifies the threshold value for enter-
ing system event messages in the
Syslog file.
System events are processed as of the
severity level "
System events are processed as of the
severity level "
System events are processed as of the
severity level "
show events config
".
Information
".
Warning
".
Critical
Diagnostics
12.1 Event and fault handling
command.
Range of values / note
-
-
-
-
-
-