Cabletest Interface - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Diagnostics
12.1 Event and fault handling
Further notes
You exit the EVENTS configuration mode with the command
12.1.5.2

cabletest interface

Description
With this command, you enable the cable test for the specified interface.
Note
Wire pairs
Wire pairs 4-5 and 7-8 of 10/100 Mbps network cables are not used.
The wire pair assignment - pin assignment is as follows (DIN 50173):
Pair 1 = pin 1-2
Pair 2 = pin 3-6
Pair 3 = pin 4-5
Pair 4 = pin 7-8
Requirement
● The interface has no active data traffic.
● You are in the Global configuration mode.
The command prompt is:
cli(config)#
Syntax
Call up the command without parameters or with the following parameter assignment:
cabletest interface <interface-type> <interface-id> [force]
The parameters have the following meaning:
Parameter
interface-type
interface-id
force
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 42)".
If you do not select any parameters from the parameter list, the default value is used.
892
Description
Type of interface
Interface identifier
Forces a
during the test
link down
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
or
end
exit
Range of values / note
Enter a valid interface.
Necessary parameter if there is a
on the interface.
link up
Configuration Manual, 06/2016, C79000-G8976-C252-11
.

Advertisement

Table of Contents
loading

Table of Contents