Smtp-Server - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

7.9.2.1

smtp-server

Description
With this command, you configure an entry for an SMTP server.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
smtp-server { ipv4 <ucast_addr> | fqdn-name <FQDN> | ipv6 <ip6_addr> } <receiver
mail-address>
The parameters have the following meaning:
Parameter
ipv4
ucast_addr
fqdn-name
FQDN
ipv6
ip6_addr
receiver mail-
address
For information on addresses and interfaces, refer to the section "Addresses and interface
names (Page 42)".
Result
An entry for the SMTP server is configured.
Further notes
You delete an SMTP server entry with the
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
Description
Keyword for an IPv4 address
IPv4 address of the SMTP server
Keyword for a domain name
Domain name (Fully Qualified Domain
Name)
Keyword for an IPv6 address
IPv6 address of the SMTP server
Name of the recipient
no smtp-server
Network protocols
7.9 SMTP Client
Note on the range if values
-
Enter a valid IPv4 unicast ad-
dress.
-
Maximum of 100 characters
-
Enter a valid IPv6 address.
Maximum of 100 characters
command.
415

Advertisement

Table of Contents
loading

Table of Contents