The parameters have the following meaning:
Parameter
ip-address
subnet-mask
prefixlength
interface
interface-type
0/a-b,0/c,...
vlan
a,b or a-b or
a,b,c-d
cpu0
service
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 42)".
The IP address 0.0.0.0 means "any manager".
If optional parameters are not specified when configuring, the manager is authorized for all
services.
Note
Configuration of the first entry
As long as the list of authorized managers is empty, access to the system is not restricted.
As soon as the list contains an entry and the "authorized-manager" command is executed,
access to the system is blocked for all others.
You should therefore configure the interface via which you access the system first because
your access is otherwise blocked.
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
Description
Specifies the network or the IP address
for which the IP manager is authorized
Subnet mask that restricts the authori-
zation
Decimal representation of the mask as
a number of "1" bits
Keyword for a an interface description
Type of interface
Module no. and port no. of the interface
Keyword for a VLAN connection
Number of a VLAN or VLAN range
the Out of Band- interface is configured
as a management Interface
Specifies the services for which the
manager is authorized.
You can select several options.
Security and authentication
11.6 Management Access Control List
Range of values / note
Enter a valid IPv4 address or a
network.
Enter a valid mask.
0 ... 32
-
Enter a valid interface.
-
Enter a valid VLAN or VLAN
range.
-
snmp
telnet
http
https
ssh
863