Loopd {Tx-Interval | Detect-Threshold | Reaction-Timeout - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

The parameters have the following meaning:
Parameter
blocked
forwarder
sender
If you do not select any parameters from the parameter list, the default value is used.
Result
It has been configured how the port handles loop detection frames.
Further notes
You can display the status of this function and other information with the
command.
12.3.3.2

loopd {tx-interval | detect-threshold | reaction-timeout}

Description
With this command you configure the send interval, threshold value and reaction time for
loop detection.
Requirement
● Loop detection is enabled
● You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
loopd {tx-interval <mSec(500-5000)> | detect-threshold <integer(1-500)> | reaction-
timeout <seconds(0-86400)>}
The parameters have the following meaning:
Parameter
tx-interval
mSec
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
Description
The forwarding of loop detection
frames is blocked.
Loop detection frames from other de-
vices are forwarded.
Loop detection frames are sent out and
forwarded.
Description
Keyword for the send interval
Specifies the send interval for loop
detection frames in milliseconds.
Diagnostics
12.3 Loop detection
Range of values / note
-
Default after enabling loop detec-
tion.
-
show loopd
Range of values / note
-
500 ... 5000
Default: 1000