No Client Config; Event Config - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

12.1.6.3

no client config

Description
With this command, you disable one of the clients that processes or forwards the messages
of the device.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
no client config {syslog|trap|email|all}
The parameters have the following meaning:
Parameter
syslog
trap
email
all
Result
The client selected for the transfer is disabled.
Further notes
You display the status of the events and the clients with the
You enable the function with the
12.1.6.4

event config

Description
With this command, you configure which of the various message types of the device will be
stored or forwarded.
The following events or message types are available:
● Message if there is cold or warm restart
● Message when there is a status change on a physical interface
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
Description
Disables the client that sends the messages to the Syslog server
Disables the client that sends the SNMP traps
Disables the client that sends the e-mails
Disables all clients at once
client config
12.1 Event and fault handling
show events config
command.
Diagnostics
command.
895

Advertisement

Table of Contents
loading