Layer 3 functions
9.2 OSPFv2 (IPv4)
Requirement
You are in the OSPF Router configuration mode.
The command prompt is as follows:
cli(config-ospf)#
Syntax
Call the command without parameters:
compatible rfc1583
Result
The compatibility with RFC 1583 is disabled.
Further notes
You enable the compatibility with the
You can display the status of this function and other information with the
ospf
9.2.3.13

default-information originate

Description
With this command, you enable the function with which a standard route is generated for
external routes into the OSPF routing domain.
Note
This command is available only with layer 3.
Requirement
You are in the OSPF Router configuration mode.
The command prompt is as follows:
cli(config-ospf)#
Syntax
Call up the command with the following parameters:
default-information originate [(
[always]
[metric <metric-value (0-0xffffff)>]
[metric-type <type (1-2)>])]